HPS Midi Var

HPS Midi Var is a spraying system used to contain odors, abate dusts and cool outside environments.

Spraying process (Osmogenic Barrier)

Odors neutralization takes place through a spraying process (osmogenic barrier), with the help of dilution water and certified specific products, deprived of polluting agents.

Labiotest osmogenic barriers guarantee abatement efficiencies of odor concentration above 80%.

All the products used are tested and guaranteed by Italian and international research institutions.

For a proper diffusion of deodorizing products, it is necessary to use adequate spraying systems, in order to guarantee:

  • suitable micronization
  • suitable timing
  • suitable times for activities
  • strategic diffusion

Main advantages

  • Elevata resa deodorizzante
  • Non vengono immesse nell'ambiente sostanze chimiche
  • Non vengono utilizzate sostanze che producono prodotti secondari
  • I componenti presenti non si ossidano e non si alterano all'aria
  • Il meccanismo di azione non viene influenzato dalla radiazione solare visibile e ultravioletta
  • All’interno dei prodotti sono presenti estratti terpenici e oli essenziali naturali che funzionano come indicatori olfattometrici di diluizione ottimale

The most important aspect of osmogenic barriers is their capacity of treating both diffused and conveyed emissions.

Description and technical characteristics

HPS midi Var is designed to supply a varying flow-rate at a constant pressure in order to feed several lines with independent nozzles.

Thanks to a board designed for an optional control that allows starting the equipment and triggering the pertaining solenoid valve, every line may be controlled by a consent coming from outside. According to the lines that are activated, the equipment ensures the necessary water flow-rate while maintaining the pressure constant on the line. With all the lines at rest, the equipment automatically turns off and it is re-started automatically at the first request from one of the lines.

Flow-rate and pressure self-regulation takes place through a pressure transducer communicating with the electric engine inverter.

Feeding voltage

400V – 50 HZ

Installed power

1,1 kW

Frame

Baseplate with rubber feet and cover made of galvanized steel having as dimensions: 780 x 450 x 500 mm

Control panel

ON–OFF switch
Warning lights as regards the system status, whether operating or in a state of alarm
Outside connector for connection to a central unit
Outside control
Contact for remote control

Hydraulic electric pump

Maximum flow-rate according to number of nozzles
Maximum pressure of 60 bars
Pump power head made of brass, ceramics pistons
Solenoid valve for water inlet

Flow-rate

4-6-8-11 l/min. (depending on the number of nozzles used)

Work pressure

Recommended 35 – max 60 bars

Revolution speed

Varying, max 1450 revolutions/min

Outside dosing unit

Filtering unit for water supply, with 50-micron filter
Proportional dosing pump without any use of electricity, with the only function of dosing, injecting and mixing

Optional

  • Pressurization unit
  • Softening unit
  • Heating cable
  • Electric board for solenoid valve control
  • Automatic dosing unit
PUMP FLOW-RATE

NUMBER OF NOZZLES (calculated at the recommended pressure *)

6 l/min - 1450 rpm

Max 48 - Min 28

8 l/min - 1450 rpm

Max 64 - Min 38

11 l/min - 1450 rpm

Max 88 - Min 52

15 l/min - 1450 rpm

Max 120 - Min 72

*At the recommended pressure, nozzles consumption is 7.5 l/h.